<noframes id="rtnld">
    <listing id="rtnld"></listing>

      <form id="rtnld"><nobr id="rtnld"></nobr></form>

      Hello! welcomeZhejiang Xikai Electric Co. , Ltd.
      Zhejiang Xikai Electric Co. , Ltd.
      Contact
      Zhejiang Xikai Electric Co. , Ltd.
      Mailbox:wzxikai@wzxikai.com
      Tel:+86 577 61666 016
      address:No.271, Weishiqi Road, Yueqing Economic Development Insuatrial Zone, Yueqing, Zhejiang.

      product list

      Indoor high voltage load switch
      14/5000 Indoor vacuum circuit breaker
      Outdoor vacuum circuit breaker
      Outdoor high voltage load switch
      Outdoor high voltage disconnector
      Outdoor drop fuse
      High voltage current limiting fuse series
      High voltage complete set
      current position:Home>Product Center

      Product Center

        • FLW34 Outdoor SF6 Gas Insulated Load Break Switch

        FLW34 Outdoor SF6 Gas Insulated Load Break Switch

        FLW34 pole mounted SF6 load break switch is used for breaking rated voltage 12/24/40.5kV,rated current 630A、50/60Hz power distribution system, closing load current and over load current of power system, it could separate automatically track sections of power distribution which faults occur. The switch is matched with electronic controller which is with the latest technology. The switch has manual, motor, remote operation modes. The electronic controller would be installed inside the stainless steel box, so it could be used in various climate conditions. Besides that, the wire/wireless modem installed inside control box could achieve remote monitoring and controlling. It’s easy and convenient for installation the switch on pole, and that could reduce the execution cost.

        Technical Information

        Technical Specification

         

         

         

        Products Type

        FLW34-12

        FLW34-24

        FLW34-40.5

        Maximum System Voltage

        15kV

        25.8kV

        40.5kV

        Rated Continuous Current

        630A

        630A

        630A

        Rated Frequency

        50/60Hz

        50/60Hz

        50/60Hz

        Short Time Withstand Current(rms)

        20kA/4sec

        25kA/1sec

        20 kA/1sec

        Mainly Active Load Current

        630A

        630A

        630A

        Number of Load-break Operations

        400times

        400times

        400times

        Short-circuit Making Current(peak)

        50kAp

        50kAp

        50kAp

        Number of Making Operations

        5times

        5 times

        5times

        Cable Charging Current

        25A

        25A

        25A

        Line Charging Current

        1.5A

        1.5A

        2A

        Closed Loop Circuit Current

        630A

        630A

        630A

        Transformer Magnetizing Current

        22A

        22A

        22A

         

        45kV

        50kV

        70kV

        Power Frequency Withstand Current Test

        50kV

        60kV

        95kV

         

        50kV

        60kV

        110kV

        Impulse Withstand Current Test(1.2x50μs)

        85kV

        150kV

        195kV

         

        95kV

        150kV

        215kV


        Overall and installation dimensions