        • (H) GW9-12 Outdoor High Voltage Ac Disconnector

        (H) GW9-12 Outdoor High Voltage Ac Disconnector

        (H) GW9-12 series outdoor high-voltage AC single-phase isolating switch (hereinafter referred to as "isolation switch"), for 10kV line to be exchanged under voltage and no load, as well as for high-voltage busbars, circuit breakers and other electrical equipment to be repaired Electrically isolated from live high voltage lines. The isolating switch complies with GB 1985-2014 "High Voltage AC Isolation Switch and Grounding Switch", DL/T486-2010 (High Voltage AC Isolation Switch and Grounding Switch) and other technical standards.

        Technical Information

        Technical Specification

         

         

         

        Rated frequency

         

        Hz

        50

        Rated voltage

         

        kV

        12

        Rated current

         

        A

        630(250)

        Rated short-time withstand current and duration

        kA/s

        20(25)/4

        Rated peak withstand current

        kA

        50(63)

        Rated short-time power frequency withstand voltage

         

        Interphase and ground (dry test)

        kV/min

        42/1

         

        Fracture (dry test)

        kV/min

        48/1

         

        Phase to ground (wet test)

        kV/min

        30/1

         

        Fracture (wet test)

        kV/min

        36/1

         

        Lightning impulse withstand voltage

         

        Phase to ground

        kV

        75

         

        Fracture

        kV

        85

        Loop resistance

         

        μΩ

        ≤80

        Mechanical life

         

        Times

        3000

        Pollution level

         

         

        e Class

        Creepage distance

         

        mm

        ≥372